350-1400 Watts HPS35 Series Total power: Input voltage: # of outputs: 350W 90-264VAC 2 One & standby Electrical Specs Input Input voltage Frequency Inrush current Efficiency Power factor Turn-on time 90-264 VAC typical 47-440 Hz 40 A peak typical @ 25C 80% typ @ full load, 230 VAC 0.98 typical @ 115 VAC, full load AC - ON 2 sec. Inhibit / Enable 160 ms CISPR 22 EN55022 Level "B" <0.5 mA max @ 230 VAC @ 60Hz (per module) CISPR 22 EN55022 Level "B" 20 ms minimum (independent of input VAC) 5 ms early warning minimum before outputs lose regulation Meets EN61000-3-2 Meets EN60950 Special Features * * * * * * * * * * * * * * * Active Power Factor Correction EN61000-3-2 compliant CISPR22, EN55022 Class-B conducted/radiated EMI EN61000 immunity standards 5VSB@2A Overvoltage protection (OVP) Overcurrent protection (OCP) Overtemperature protection (OTP) AC OK signal and indicator LED DC OK signal and indicator LED Remote inhibit Remote Sense on main output Hot Plug N+1 Redundant Optional I2C board (pending) Voltage Monitoring Current Monitoring Remote on/off DC OK / AC OK Temperature Fan fail EMI filter standard Leakage current standard Radiated EMI Holdup time AC OK Harmonic distortion Isolation Output 5% of nominal output voltage <3% 1% of Vout Pk - Pk (20 MHz bandwidth) Dynamic response 4% with 50% load step Recovery time To within 1% in <300 sec Overcurrent protection 115%-130% of rated output current Short circuit protection Protected for continuous short circuit. Auto recovery. Overvoltage protection 120 - 140% . AC Reset. Reverse voltage protection 100% of rated output current Thermal protection Main and Aux disabled when internal temp exceeds safe operating range. Remote sense Up to 0.5 V total drop Single wire parallel Current share to within 10% of total rated current on main output DC OK 5% of nominal Minimum load* None required (as a standalone module) Standby voltage 5 VDC @2A max. present whenever AC input is applied Global Inhibit Logic "0" *3A minimum required for current share operation Adjustability Overall reg Ripple Environmental Operating temperature: 0C to +50C ambient, derate output @ 2.5% per degree from 50C to 70C Shock: Operating - 4g, half since, 22 ms minimum duration, all 6 faces Non-operating: 30g, half since, 6 ms minimum duration, all 6 faces Random Vibration Operating: 1g rms, 20 min/axis Non-operating: 12.5g rms, 20min/axis Humidity: 95% non-condensing Storage temperature: -40C to +85C Temperature coefficient: 0.04% per C Cooling: Internal DC fans Safety UL CSA TUV CB CE UL60950-1, 1st Ed. (April 1, 2003) CSA C22.2 60950-1-03 EN60950-1:2001 (1st Ed.) IEC60950-1, 1st Ed. (2001) Mark (LVD) Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-96622 rev 02.24.05 AMERICAS 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 ASIA Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 HPS35 Modules Watts Input Voltage Module ID Code L W Module Code HPS35 Max. Size (H x W x L) 1.6" x 4.3" x 10.5" Max. Module Power 350 W Number Unit per Rack Weight (lbs) 4 3.2 350 90-264 HPS35 Volts 12.0 48.0 Output Amps 29.2 7.3 Power 35 = 350 W 50 = 500 W Special Options & Modifications Contact Astec HPS Output Voltage L = 12 V W = 48 V NNR 0 0 0 XXX HPS35L-NNR-000 N 0 HPS35L-NNR-000 MAXIMUM OUTPUT POWER IS 350W DATE: YYWW S/N: MMMMWWSSSSRRC MADE IN PHILIPPINES 53.8 90 - 240VAC - 40A 50/60 Hz REV: XX A/C CODE: XXXX 73-811-029 SERIAL NO.: 7.6 www.astecpower.com INPUT: +12V / 29A OUTPUT: Pin Assignments HPS35 Module Top Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Description AC (L) BLANK AC (N) BLANK GND SWP 5V RTN COMMON COMMON COMMON COMMON COMMON COMMON V OUT V OUT V OUT V OUT V OUT V OUT BLANK +5 STANDBY TBA FAN MON I2C CLK Bottom Pin A B C D E F H J K L M N P R S T U V W X Y Z AA BB Description AC (L) BLANK AC (N) BLANK GND -SENSE +SENSE COMMON COMMON COMMON COMMON COMMON COMMON V OUT V OUT V OUT V OUT V OUT V OUT INHIBIT TBA AC OK DC OK I2C DATA TOP SIDE 1-24 1 2 3 C 4 5 6 F 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 K L MNP R S T UV WX Y Z AA AB AB DE HJ Unit Connector Card Edge Connector with gold fingers double-sided 1.6mm FR-4 PCB Mating connector: EDAC 307-048-520-201 or equivalent Rating: 5A per contact Pin 6 - SWP (IN/OUT Signal) (Single Wire Parallel) SWP Pin is used when connecting units in parallel to achieve current sharing. Current share accuracy is typically 10% of full load. Note: SWP Voltage is 5V at 100% load current Pin 23 - Fan Monitor (OUT Signal) Pin X - Module Inhibit (IN Signal) Pin Z - AC OK (OUT Signal) Note: Hi state: Source 100uA @ 4V Low State: Sink 10mA @ 0.5V Pin F - --Remote Sense R Pin H - + Remote Sense Compensates for up to 0.5V drop. Recommended shielded twisted wire pair. Pin AA - DC OK (OUT Signal) 154 North America (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211 Asia (HK): 852-2437-9662 rev 02.24.05 HPS35 Series DRAWINGS Racks Watts Input Voltage Module Used Rack ID Code L W 1400 (fully populated) 90-264 HPS35 HPR1 Volts 12.0 48.0 Output Amps 116.8 29.2 AMERICAS 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 ASIA Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 System Code HPR1 Max. Size (H x W x L) 1.75" x 19.0" x 13.0" Max. System Power 1400 W Module Distribution (4 ea) HPS35 Standard Size 1U Unit Weight (lbs.) 8.6 HPR1 - Standard Options 00 = No options 01 = Local sense HPR1 -00 0 482.6 22.0 AC Cord: (North America) For all other countries, please contact factory. 1) Quail Electronics Series 5050 or equivalent (15A/125V) Supply End - NEMA 5-15P Equipment End - IEC 60320-C19 2) Quail Electronics Series 5052 or equivalent (20A/125V) Supply ENd - NEMA 5-20P Equipment End - IEC60320-C19 25.0 + RTN 13.4 468.8 343.2 442.0 31.7 + RTN 43.7 www.astecpower.com DATE: YYWW S/N: MMMMWWSSSSRRC MADE IN PHILIPPINES 50/60 Hz 90 - 240VAC - 40A INPUT: SERIAL NO.: MAXIMUM OUTPUT POWER IS 1400W HPR1-00 REV: XX A/C CODE: XXXX 73-810-002 +12V / 29A OUTPUT: Blank Panel: Astec P/N 73-686-000 330.2 155 D-sub Connector Pin outs HPR1 -00 0 Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Description 5V Return (std-by) + Remote Sense - Remote Sense 5V Stand by Unused Module Inhibit DC OK AC OK I2C_ADD#1 I2C_ADD#2 Fan Monitor Global AC OK Module Inhibit DC OK AC OK I2C_ADD#1 I2C_ADD#2 Fan Monitor Global Inhibit Pin 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Description I2C CLOCK I2C DATA SWP Unused (I2C_INT) Module Inhibit DC OK AC OK I2C_ADD#1 I2C_ADD#2 Fan Monitor Unused Module Inhibit DC OK AC OK I2C_ADD#1 I2C_ADD#2 Fan Monitor Unused Pin 2 + Remote Sense Pin 3 - Remote Sense Compensates for up to 0.5V drop. Recommended shielded twisted wire pair. Pin 12 - Global AC OK (OUT signal) DC OK (OUT Signal) S L O T 1 S L O T 3 Note: DC OK signals for each slot in the rack is accessible in the D-sub connector (J18). Refer to Connector Pin-out table for pin assignments. Pin 1 is the Return Pin. Note: AC OK signals are OR'ed together internally. If any module fails, the LED on the affected module will be off and the logic signal will indicate AC NOT OK. Pin 19 - Global Inhibit (IN signal) AC OK (OUT Signal) S L O T 2 S L O T 4 Note: All outputs disabled when Pin 19 is open or High. Note: AC OK signals for each slot in the rack is accessible in the D-sub connector (J18). Refer to Connector Pin-out table for pin assignments. Pin 1 is the Return Pin. Hi state: Source 100uA @ 4V Low State: Sink 10mA @ 0.5V Pin 22 - SWP (IN/OUT signal) SWP Pin is used when Fan Monitor (OUT Signal) connecting racks in parallel to achieve current sharing. Current share accuracy is typically 10% of full load. Note: SWP Voltage is 5V at 100% load current. Module Inhibit (IN Signal) Note: Fan Monitor signals for each slot in the rack is accessible in the D-sub connector (J18). Refer to Connector Pin-out table for pin assignments. Pin 1 is the Return Pin. I2C_ADD#1 I2C_ADD#2 TBD PSU Connector 617-A-037-P-AJ-1-21 (Male socket) Amphenol Note: Module Inhibit signals for each slot in the rack is accessible in the D-sub connector (J18). Refer to Connector Pinout table for pin assignments. Pin 1 is the Return Pin. Pin Out Diagram D-sub Connector (male) Mating Connector 617-A-037-S-AJ-1-20 (Female socket) Amphenol Pin Out Diagram D-sub Connector (female) 156 North America (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211 Asia (HK): 852-2437-9662 rev 02.24.05 |
Price & Availability of HPS35 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |